Landfill Liner Systems

A liner is the engineered floor of a landfill or impoundment. Its job is to keep leachate inside, where it can be collected and treated, and out of groundwater.

Composite liner cross-section From top: waste, protective soil, drainage gravel with collection pipe, geotextile, HDPE geomembrane, compacted clay liner, subgrade. WasteProtective soilDrainage layer + pipekeeps head < 30 cm GeotextileGeomembrane (60-mil HDPE)Compacted clay, ≥ 2 ftk ≤ 1×10⁻⁷ cm/sSubgrade
Typical composite liner with leachate collection (not to scale).

The building blocks

Compacted clay liner (CCL)
Fine-grained soil compacted wet of optimum water content in lifts to a low hydraulic conductivity, commonly specified at or below 1×10−7 cm/s (1×10−9 m/s). Performance depends on soil type, compaction, clod size and protection from desiccation and freezing.
Geomembrane (GM)
A thin polymer sheet, most often high-density polyethylene (HDPE), that is practically impermeable to water. Leakage occurs mainly through holes and seam defects, so construction quality assurance is critical. Organic compounds can still diffuse through the polymer.
Geosynthetic clay liner (GCL)
A thin layer of sodium bentonite held between geotextiles or bonded to a geomembrane. Hydrated with water, it reaches very low hydraulic conductivity, but it is sensitive to the chemistry of the permeating liquid. See the GCL guide.
Leachate collection and removal system (LCRS)
A drainage layer of gravel or a geonet/geocomposite with perforated pipes that keeps the liquid head on the liner low and conveys leachate to sumps.

Composite liners

A composite liner places a geomembrane in intimate contact with a low-permeability soil or GCL. Each component covers the other’s weakness: the soil limits flow through the inevitable small holes in the geomembrane, and the geomembrane limits the area of soil exposed to leachate. Leakage through a well-built composite liner is typically orders of magnitude lower than through either component alone.

US federal rules for municipal solid waste landfills (40 CFR 258.40) set the default design as a composite liner with an upper geomembrane at least 30 mil thick (60 mil if HDPE) over at least 2 ft of compacted soil with hydraulic conductivity no greater than 1×10−7 cm/s, and a leachate collection system that keeps the head on the liner below 30 cm. The coal combustion residuals (CCR) rule at 40 CFR 257.70 uses a similar composite liner for new CCR units. See coal ash disposal.

Double liners and leak detection

A double liner adds a second liner beneath the first, separated by a leak detection drainage layer. Liquid that reaches the leak detection layer is a direct, measurable sign of primary liner leakage, and it is collected before it can reach the secondary liner. Hazardous waste landfills and some state programs, such as Florida’s for certain facilities, require double liners. Whether a given double liner is “equivalent” to a single composite liner depends on the components and is usually judged by comparing leakage and contaminant mass transport.

Comparing liner types

LinerMain strengthMain vulnerability
Compacted clayThick and self-healing; attenuates contaminants by sorptionDesiccation cracking, freeze–thaw, construction variability
Geomembrane aloneNear-zero advective flow through intact sheetHoles, seam defects, wrinkles; organic diffusion
GCLThin, fast to install, low hydraulic conductivityChemical incompatibility, panel shrinkage, low confining stress
CompositeVery low leakage when in good contactWrinkles break contact; still needs quality assurance
Double with leak detectionRedundancy plus measurable leakageCost, complexity, slope stability at interfaces

Estimating leakage through geomembrane holes

For a circular hole in a geomembrane over a low-permeability soil, a widely used empirical relation (Giroud, 1997) is

Q = C · [1 + 0.1 (h/ts)0.95] · a0.1 · h0.9 · ks0.74

where Q is the leakage rate (m³/s), h the head on the liner (m), ts the soil thickness (m), a the hole area (m²), ks the soil hydraulic conductivity (m/s), and C ≈ 0.21 for good contact or 1.15 for poor contact. The equation is empirical and must be used in SI units. Its main lesson is practical: keeping the head low and the contact intimate matters as much as the soil’s conductivity.

Keep learning